https://nova.newcastle.edu.au/vital/access/ /manager/Index ${session.getAttribute("locale")} 5 International comparison of cosmetic outcomes of breast conserving surgery and radiation therapy for women with ductal carcinoma in situ of the breast https://nova.newcastle.edu.au/vital/access/ /manager/Repository/uon:40147 in situ (DCIS) of the breast. Materials and methods: Baseline and 3-year cosmesis were assessed using the European Organization for Research and Treatment of Cancer (EORTC) Cosmetic Rating System and digital images in a randomised trial of non-low risk DCIS treated with postoperative WBI +/− TBB. Baseline cosmesis was assessed for four geographic clusters of treating centres. Cosmetic failure was a global score of fair or poor. Cosmetic deterioration was a score change from excellent or good at baseline to fair or poor at three years. Odds ratios for cosmetic deterioration by WBI dose-fractionation and TBB use were calculated for both scoring systems. Results: 1608 women were enrolled from 11 countries between 2007 and 2014. 85–90% had excellent or good baseline cosmesis independent of geography or assessment method. TBB (16 Gy in 8 fractions) was associated with a >2-fold risk of cosmetic deterioration (p < 0.001). Hypofractionated WBI (42.5 Gy in 16 fractions) achieved statistically similar 3-year cosmesis compared to conventional WBI (50 Gy in 25 fractions) (p ≥ 0.18). The adverse impact of a TBB was not significantly associated with WBI fractionation (interaction p ≥ 0.30). Conclusions: Cosmetic failure from BCS was similar across international jurisdictions. A TBB of 16 Gy increased the rate of cosmetic deterioration. Hypofractionated WBI achieved similar 3-year cosmesis as conventional WBI in women treated with BCS for DCIS.]]> Thu 11 Aug 2022 14:56:25 AEST ]]> First clinical experience with real-time portal imaging-based breath-hold monitoring in tangential breast radiotherapy https://nova.newcastle.edu.au/vital/access/ /manager/Repository/uon:51352 , per tangent were compared to the planned mLDs; differences between the largest and smallest observed () per tangent were calculated. Results: For 56% (162/288) of the tangents tested, were outside the tolerance window. All but one patient had at least one fraction showing this behaviour. The largest difference found between an and its planned mLD was −16.9 mm. The accuracy of patient positioning and the quality of marker-block-based DIBH guidance contributed to the differences. Fractions with patient position verification using a single EPID image taken before treatment showed a lower rate (34%), suggesting reassessment of setup procedures. Conclusions: Real-time treatment monitoring of the internal anatomy during DIBH delivery of tangential breast RT is feasible and useful. The new system requires no additional radiation for the patient.]]> Fri 01 Sep 2023 13:36:10 AEST ]]>